Ring Damp

RC snubber C, R, and loss

NederlandsEnglish한국어العربيةDeutschFrancais日本語EspanolItalianoSvenskaDanskNorsk bokmalSuomiPortugues (Brasil)Portugues (Portugal)

RC snubber capacitance, resistance, and loss

Example energy capacitance

Capacitance comes from the energy equation. The entered capacitance is not used in this mode.

Uitgewerkt voorbeeld

CRloss40 nF10 ohm8 W

Energy calculation

Energy capacitance 40 nF

C_energy = (L_H * I^2) / Delta_V^2. The inductance unit is converted to henry before this equation.

Selected capacitance

Capacitance used 40 nF

Energy mode uses C = (L * I^2) / Delta_V^2. Entered mode uses the capacitance and unit you selected.

Damping resistance 10 ohm

R = 2 * zeta * sqrt(L / C)

Loss

Resistor loss 8 W

P = C * V_peak^2 * f_Hz. Hz, kHz, and MHz are converted to hertz first.

Capacitor voltage rating and resistor power rating need measurement on the real circuit. No switch part number is stored here.

dv/dt and time

dv/dt 250 V/µs

dv/dt = V_peak / (R * C) in V/s, shown as V/µs (volts per microsecond).

Minimum on time 1.2 µs

t_on = 3 * R * C, shown in µs (microseconds).

Zeta from 0.7 to 1.0 is a usual damping note, not a clamp. The AC power equation is not used because X_c is not defined.